Self-Cleaning Process pH/ORP Electrodes and Mounting Kits
By-pass
|
In-line
|
Submersion
|
All electrodes can be ordered online!
Self Cleaning pH and ORP Double Junction Electrodes
Use these self cleaning, double junction electrodes for both ATC (automatic temperature compensated) and MTC (manual temperature compensated) applications. These electrodes are ideal for use in solutions that may abrade or coat conventional electrodes. The durable, double junction, flat surfaced sensor minimizes the possibility of reference clogging, even in oily waste water when measuring samples flow at an adequate velocity (typically 3 to 5 GPM). These electrodes are fast responding (95% in less than 5 seconds) over the full 0-14 pH range and are suitable for use from 10-76° C (50-170° F) at 100 psig. Wetted materials consist of CPVC, polyethylene, vitron and glass (ORP probes also include platinum). Choice of ATC (automatic temperature compensated) or MTC (manual temperature compensated) kits. ATC kits are especially applicable when solutions are outside of 4 to 10 pH or 15-35° C range. Electrode installation is easy - a simple quarter turn installs or removes the probe from its process mount; its double 0-ring seals the mounting assembly and the cable.
How to Select your pH and ORP Process Electrode Mounting Kit - It's as Easy as 1-2-3.
1. Select your measuring parameter: pH or ORP (Redox)
2. Select your mounting preference; in-line, by-pass (side stream) or submersion. In-line Mounting: ideal for piping systems where flow can be shut off for electrode maintenance and where flow rates match the application's needs; for example, turbulent flow is needed in self-cleaning application. A simple, re-useable 3/4" MNPT gland is used to mount the electrode in mating opening. By-pass (side stream) Line Mounting; allow electrodes to be mounted in convenient locations and are particularly useful in applications involving oily coatings, low suspended solids contents or moderately viscous solutions. This mounting hardware allows the velocity past the electrode to be controlled. In the 3/4" flow cell's restricted 1-4" flow channel each GPM flow provides a 2 ft/sec velocity past the electrode's sensing surface; flow rates of 3 to 5 GPM provide adequate cleaning velocities. In viscous solution applications these flow rates may be difficult to achieve; however, lower rates still provide flow in sheer to assure that fresh material is at the measuring surface. Submersion Mounting; useful for making measurements in tanks, flumes, and sewer lines. It is well suited for applications with high suspended solids or where flocculating operations require low velocities. It is also useful for coating problems in tanks which have high agitation.
3. Select your cable length: 10 ft and 25 ft cable length are standard; however, special lengths are available. All electrode cable is terminated with a BNC connector; other connectors are available.
Price of kits include electrode, cable (10' or 25') with BNC connector which connects to the meter plus the mounting hardware assembly. ATC kits also include Corning (phono) jack for temperature connection. ORP kits do not include ATC.
Standard ATC kits contain a 100 ohm platinum RTD sensor. Other resistance values for automatic temperature compensation are available; when inquiring specify the ohms value at 25 ° C.
We accept credit card and Paypal orders online only from customers in the United States.
Self Cleaning: In-line Kits
| Cat No. | Model/Description |
Price |
|
| 12E70-10 | MTC pH In-Line Kit (10') | $192.00 |
|
| 12E70-25 | MTC pH In-Line Kit (25') | 199.00 |
|
| 12E71-10 | ORP In-Line Kit (10') | 215.50 |
|
| 12E71-25 | ORP In-Line Kit (25') | 223.50 |
|
| 12E72-10 | ATC pH In-Line (10') | 315.50 |
|
| 12E72-25 | ATC pH In-Line (25') | 346.25 |
Self Cleaning: By-Pass (side-stream) Kits
| 12E73-10 | MTC pH By-Pass Kit (10') | $279.00 |
|
| 12E73-25 | MTC pH By-Pass Kit (25') | 287.00 |
|
| 12E74-10 | ORP By-Pass Kit (10') | 303.50 |
|
| 12E74-25 | ORP By-Pass Kit (25') | 311.50 |
|
| 12E75-10 | ATC pH By-Pass Kit (10') | 368.50 |
|
| 12E75-25 | ATC pH By-Pass Kit (25') | 399.25 |
Self Cleaning: Submersion Kits
| 12E76-10 | MTC pH Submersion Kit (10') | $198.00 |
|
| 12E76-25 | MTC pH Submersion Kit (25') | 195.00 |
|
| 12E77-10 | ORP pH Submersion Kit (10') | 209.00 |
|
| 12E77-25 | ORP pH Submersion Kit (25') | 214.00 |
|
| 12E78-10 | ATC pH Submersion Kit (10') | 273.00 |
|
| 12E78-25 | ATC pH Submersion Kit (25') | 295.00 |
Spare Self Cleaning Electrodes
| 12E79 | S660CD In-line pH Electrode | $140.00 |
|
| 12E80 | S660CD-ORP In-Line ORP Electrode | 165.00 |
|
| 12E81 | S645CD By-Pass pH Electrode | 139.00 |
|
| 12E82 | S645CD-ORP By-Pass ORP Electrode | 168.00 |
|
| 12E83 | S650CD Submersion pH Electrode | 143.00 |
|
| 12E84 | S650CD-ORP Submersion ORP Electrode | 173.00 |
Note: Special cable lengths in excess of 25 ft can be special ordered; add $1.00/ft for MTC kits and $2.50/ft for ATC kits. Also, connectors other than BNC are available on a special order basis.
IMPORTANT
NOTICE -
If you need a product and it has not yet
been set
up for on-line purchase, please
place your order by
credit card toll-free to
1-800-325-3875. We will honor the prices
shown on the website.
Hosting provided by
3N1 Creative © Kernco Instruments Inc.