Home
Email
PRODUCT LINKS
Anemometers
Air Speed, Temperature and Relative Humidity
Event Recorders - Measures downtime &
production time
4-20mA
Amperometer-Calibrator
Monitor & regulate 4-20mA outputs, Measure
currents, LCD display, Calibrate recorders & other features
Dangerous Gas Leak Detectors
Over 100 combustible and toxic gases
Gas Detectors - Wall mounted, visual/audio
alarms
Gas Detectors - Portable, visual/audio alarms
Gas Calibrating Kits
Humidity/Temperature Indicators
Humidity/Temperature Transmitters
Industrial Fluids Testers
Coolants, cutting oils, lubricants & other fluids
Optical & digital
Infra-Red Thermometers
Moisture Meters
Paper
Cotton
pH/Conductivity Meters
pH Monitors - 4-20mA
pH/mV/Temperature Meters
pH/ORP Electrodes
pH/ORP Simulators
pH/ORP Transmitters
REFRACTOMETERS COMPLETE LINE
Atago Refractometers
Industrial Fluids Testers
Coolants, cutting oils, lubricants & other fluids
Optical & digital
Reichert (Leica)
Refractometers
Over 10 models - Brix, salinity, clinical, industrial fluids, bench top Abbe
type, brake fluids and battery/coolants
Clinical Refractometers
Measure urine s.g., serum or plasma protein, cupric sulphate s.g. used in
hospital labs, vet clinics and other health centers
Digital Desktop Refractometers
Large 2.5" LCD display, 4 models, 5 Year Warranty,
Hi/Low alarm feature
Kernco's Special Refractometers
Discounts up to 50% on some. 8 different ranges
ATC Refractometers
Temperature Compensated, 7 different ranges, Large discounts
Kernco's Multi Range Models - 0-72%, 0-80%
and 0-90%
New Digital Portable Refractometers, 5 Year warranty,
6 models
Starch Refractometers
Static Meter
Detect static charges
Locate source of static
Hand-held, digital
Stroboscopes
7 Models available
Tachometers
Contact Type
Contact/Non Contact Type
Non-Contact Tachometer Combination Photo
Tachometer/Stroboscope
Turbidity Meters
Ultrasonic Leak Detectors
Vibration Meters
| |
-
Hanna's EC214 & EC215 Multi-Range
Conductivity Meters with ATC - Distributed by Kernco
- Platinum Probe: This 4 ring probe is easier to clean, more stable and
withstands higher temperatures.
- 4 Conductivity Ranges: The 4 ranges available will cover every application
from deionized water to brine with a single probe.
- Temperature Compensation: EC214 offers manual compensation, while EC215
performs automatic compensation standardized to 25°C.
- Wide Range of Calibration Solutions Choose from an extensive range of
calibration solutions to get the most out of your meter.
EC214 and EC215 are
professional multi-range conductivity bench meters suited for everyday laboratory use.
These instruments are designed to be easy to operate without compromising accuracy and
reliability. EC214 and EC215 perform measurements in four separate ranges allowing the
user to switch applications without having to change the probe or recalibrate the
conductivity meter. Calibration is simplified by referring to the chart printed on the
front of the instrument showing Standard Conductivity values at 25°C. These instruments
are able to perform multi-range measurements by utilizing an innovative platinum 4-ring
probe. Platinum rings provide more stable results, withstand higher temperatures and are
easier to clean. With EC214 temperature compensation is performed manually with a simple
adjustment of the knob on the front of the instrument. Temperature compensation with the
EC215 is automatic thanks to a built-in temperature sensor in the conductivity probe.
EC215 allows the user to adjust the temperature coefficient from 0 to 2.5% per degree
Celsius, an important plus in acidic, alkaline or highly saline samples. These robust
bench meters apply the latest sensor technology without complicating their operations.
Both conductivity meters are supplied with a platinum probe, transformer and
dust cover, probes are included in price.
We accept
credit card and Paypal orders online only from customers in the United States.
SPECIFICATIONS:
| Range: |
0.0 to 199.9µS/cm
0 to 1999µS/cm
0.00 to 19.99µS/cm
0.0 to 199.9µS/cm |
| Resolution : |
0.1µS/cm; 1µS/cm |
| Accuracy (@20°C): |
±1% F.S. (excluding probe error) |
| Typical EMC Devication: |
±1% F.S. |
| Calibration: |
Manual 1 point with knob |
| Temperature Compensation: |
EC214 Manual from 0 to 50°C with an adjustable b of 2% per °C |
|
EC215 Automatic from 0 to 50°C with an adjustable b or 2.5% per °C |
| Probe: |
EC214 HI76300 conductivity probe with platinum 4-ring, cable 1m
(included) |
|
EC215 HI76303 conductivity probe with platinum 4-ring, temp. sensor,
cable 1m (included) |
| Power Supply: |
12VDC power adapter (included) |
| Environment: |
0 to 50°C (32 to 122°F); R.H. 95% |
| Dimensions: |
240 x 182 x 74mm (9.4 x 7.1 x 2.9) |
| Weight: |
1 Kg (36 oz.) |
| Catalog No. |
Model/Description |
Price |
|
| 13C31 |
EC214 Conductivity Meter with ATC
(HI76300 conductivity probe)
Supplied with a platinum probe, transformer and dust cover,
probes are included in price. |
$565.00 |
|
| EC215 |
EC215 Conductivity Meter with ATC
(HI76303 conductivity probe)
Supplied with a platinum probe, transformer and dust cover,
probes are included in price. |
668.00 |
|
| 13C29-A |
HI76300 Conductivity Probe for EC214 |
185.00 |
|
| HI76303 |
HI76303 Conductivity Probe for EC215 |
214.00 |
|
| 13J3 |
HI7030L Conductivity Solution, 12,880
µS/cm (460mL) |
20.00 |
|
| 13J4 |
HI7031L Conductivity Solution,
1,413µS/cm
(460mL) |
20.00 |
|
| 13J5 |
HI7033L Conductivity Solution,
84µS/cm
(460mL) |
25.00 |
|
| 13J6 |
HI7034L Conductivity Solution, 80,000µS/cm
(460mL) |
25.00 |
|
| 13J7 |
HI7035L Conductivity Solution, 111,800µS/cm
(460mL) |
25.00 |
|
IMPORTANT
NOTICE -
If you need a product and it has not yet
been set
up for on-line purchase, please
place your order by
credit card toll-free to
1-800-325-3875. We will honor the prices
shown on the website.
Any problems or
questions call 1-800-325-3875 or Email
or fax
to 915-852-4084.
-
- Prices shown
apply to sales to companies within the United States.
- For sales
outside the US contact Kernco Instruments for
appropriate prices for your country.

Hosting provided
by
3N1
Creative © Kernco Instruments Inc.
|